| 47843.1 |
26 GA LOW RIB PANEL |
26 GA LOW RIB PANEL OVER 7/16" OSB NON HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-232 Other: -116 psf fastening pattern 7.5"- 1.5"- 7.5"-1.5" 7.5"- 1.5"- 7.5"-1.5" @ 12" spacing Install per manufacturers details for use in NON HVHZ |
Installation Instructions FL47843_R0_II_newSS AGCOR LLC Report.pdf Verified By: PRI Construction Materials Technologies, LLC Created by Independent Third Party: Yes Evaluation Reports FL47843_R0_AE_newSS AGCOR LLC Report.pdf FL47843_R0_AE_UL 580 AND UL 1897 TEST REPORT FLORIDA APPROVAL 26ga AG.pdf Created by Independent Third Party: Yes |
|
|
| 47843.2 |
29 GA LOW RIB PANEL |
29 GA LOW RIB PANEL OVER 7/16" OSB NON HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-187 Other: -93.5 psf fastening pattern 7.5"- 1.5" 7.5"- 1.5" 7.5"- 1.5" 7.5"- 1.5" @ 12" spacing Install per manufacturers details for use in NON HVHZ |
Installation Instructions FL47843_R0_II_newSS AGCOR LLC Report.pdf Verified By: PRI Construction Materials Technologies, LLC Created by Independent Third Party: Yes Evaluation Reports FL47843_R0_AE_newSS AGCOR LLC Report.pdf FL47843_R0_AE_UL 580 AND UL 1897 TEST REPORT FLORIDA APPROVAL 29ga AG.pdf Created by Independent Third Party: Yes |