| 47879.1 |
1 - "CMP S2500" 16" wide |
24 Gauge, 16" Wide Steel Roof panel attached to 16 gauge Steel Purlins mechanically seamed with two-piece floating panel clips |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +See/-TableA Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL47879_R1_II_1_S2500_24ga_16in_SteelPurlins_EVALREPORT.pdf Verified By: James L. Buckner, P.E. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47879_R1_AE_1_S2500_24ga_16in_SteelPurlins_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 47879.2 |
2- "CMP S2500" 18" wide |
24 Gauge, 18" Wide Steel Roof panel attached to 16 gauge Steel Purlins mechanically seamed with two-piece floating panel clips |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-TableA Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL47879_R1_II_2_S2500_24ga_18in_SteelPurlins_EVALREPORT.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47879_R1_AE_2_S2500_24ga_18in_SteelPurlins_EVALREPORT.pdf Created by Independent Third Party: Yes |