| 704.1 |
Loc-Seam 360 |
Min 24 ga., max 16" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-157.5 Other: Uplift load of 157.5 psf at clip and S-5-U Mini clamp spacing of 24" o.c. |
Installation Instructions FL704_R10_II_EvaluationReportC2889_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL704_R10_AE_EvaluationReportC2889_1.pdf Created by Independent Third Party: Yes |
|
|
| 704.2 |
Loc-Seam 90 |
Min 24 ga., max 16" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Uplift load of 52.5 psf @ support spacing of 60.25" o.c. |
Installation Instructions FL704_R10_II_EvaluationReportC2889_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL704_R10_AE_EvaluationReportC2889_2.pdf Created by Independent Third Party: Yes |
|
|
| 704.3 |
R-Panel |
Min. 26 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limitations and load tables. |
Installation Instructions FL704_R10_II_EvaluationReportC2889_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL704_R10_AE_EvaluationReportC2889_3.pdf Created by Independent Third Party: Yes |
|
|
| 704.4 |
R-Panel |
Min. 24 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +85.8/-169 Other: Maximum uplift load of 169 psf @ support spacing of 2' o.c. |
Installation Instructions FL704_R10_II_D2889_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL704_R10_AE_EvaluationReportC2889_4.pdf Created by Independent Third Party: Yes |
|
|
| 704.5 |
SS360 |
Min 24 ga., 24" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: Uplift load of 52.5 psf @ support spacing of 60.187" o.c. |
Installation Instructions FL704_R10_II_EvaluationReportC2889_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL704_R10_AE_EvaluationReportC2889_5.pdf Created by Independent Third Party: Yes |
|
|
| 704.6 |
SSII |
Min 24 ga., 24" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: Uplift load of 52.5 psf @ support spacing of 60.187" o.c. |
Installation Instructions FL704_R10_II_EvaluationReportC2889_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL704_R10_AE_EvaluationReportC2889_6.pdf Created by Independent Third Party: Yes |