| 18239.1 |
9660/9770 PW |
72x72 Finless Frame Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: FW-LC55, Missile Level D, Wind Zone 3. Glass is bedded in Pecora 896 silicone with a 1/2" glazing bite. |
Certification Agency Certificate FL18239_R7_C_CAC_MI Windows - 9660-9770 PW Dir. Set (Fin Finless) (2) Impact.pdf Quality Assurance Contract Expiration Date 04/17/2031 Installation Instructions FL18239_R7_II_08-01824B1-2.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL18239_R7_AE_512510B.pdf Created by Independent Third Party: Yes |
|
|
| 18239.2 |
9660/9770 PW |
72x72 Fin Frame Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: FW-LC55, Missile Level D, Wind Zone 3. Glass is bedded in Pecora 896 silicone with a 1/2" glazing bite. |
Certification Agency Certificate FL18239_R7_C_CAC_MI Windows - 9660-9770 PW Dir. Set (Fin Finless) (2) Impact.pdf Quality Assurance Contract Expiration Date 04/17/2031 Installation Instructions FL18239_R7_II_08-01824B1-2.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL18239_R7_AE_512510B.pdf Created by Independent Third Party: Yes |
|
|
| 18239.3 |
9660/9770 PW Direct Set |
72x72 Fin Frame |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: FW-LC60 |
Certification Agency Certificate FL18239_R7_C_CAC_MI Windows - 1665-1675-9660-9770 PW Direct Set (Fin) (1) Jan. 2026 (ext.5).pdf Quality Assurance Contract Expiration Date 02/24/2031 Installation Instructions FL18239_R7_II_08-01825B3-4.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL18239_R7_AE_512511B.pdf Created by Independent Third Party: Yes |
|
|
| 18239.4 |
9770 Direct Set PW |
72x72 Finless Frame |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-55 Other: FW-LC55 |
Certification Agency Certificate FL18239_R7_C_CAC_MI Windows - 1665-1675-9660-9770 PW Direct Set (Finless) (1) Jan. 2026 (ext.5).pdf Quality Assurance Contract Expiration Date 02/24/2031 Installation Instructions FL18239_R7_II_08-01825B3-4.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL18239_R7_AE_512511B.pdf Created by Independent Third Party: Yes |