| 22307.1 |
Premium Vinyl |
Double Hung Tilt 3 Panel (XXX) 108" x 72" (1/8" PVB Laminate in - 1/8" annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3 Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL22307_R5_C_CAC_JELD-WEN - Premium Vinyl DH Triple (3b) Impact Mar. 2026 (ext.5) 22307.1.pdf Quality Assurance Contract Expiration Date 05/19/2032 Installation Instructions FL22307_R5_II_PV TDH XXX IMP WZ3 FBC 108x72 SS 2018-03-06.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL22307_R5_AE_PER5525 SS 2018-03-06.pdf Created by Independent Third Party: Yes |
|
|
| 22307.2 |
Premium Vinyl (V-4500) |
Double Hung Tilt 48" x 77" (1/4" PVB Laminate in - 1/8" annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-55 Other: Wind Zone 2 Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL22307_R5_C_CAC_JELD-WEN - Premium Vinyl DH (4c) Impact Mar. 2026 (ext.5) 22307.2.pdf Quality Assurance Contract Expiration Date 02/06/2032 Installation Instructions FL22307_R5_II_Premium Vinyl Tilt Double Hung Impact WZ2 Install Package 48 x 77_12-26-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL22307_R5_AE_PER5520 SS 2018-03-06.pdf Created by Independent Third Party: Yes |
|
|
| 22307.3 |
Premium Vinyl (V-4500) |
Double Hung Tilt 48" x 77" (5/16" PVB Laminate in - 1/8" annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-55 Other: Wind Zone 3 Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL22307_R5_C_CAC_LC-PG50_48x77_WZ2 22307.3.pdf Quality Assurance Contract Expiration Date 02/06/2032 Installation Instructions FL22307_R5_II_PV TDH IMP WZ3 FBC 48x77 SS 2018-03-06.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL22307_R5_AE_PER5516 SS 2018-03-06.pdf Created by Independent Third Party: Yes |
|
|
| 22307.4 |
Premium Vinyl (V-4500) |
Double Hung Tilt 3 Panel (XXX) 108" x 72" (1/4" PVB Laminate in - 1/8" annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 2 Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL22307_R5_C_CAC_XXX-LC-PG50_108x72_WZ2.pdf Quality Assurance Contract Expiration Date 05/19/2027 Installation Instructions FL22307_R5_II_PV TDH XXX IMP WZ2 FBC 108x72 SS 2018-03-06.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL22307_R5_AE_PER5522 SS 2018-03-06.pdf Created by Independent Third Party: Yes |