| 22382.1 |
Series 4760 Picture Window |
Series 4760 Picture Window, L.M. Impact, HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL22382_R3_C_CAC_10-123_C1R0.pdf Quality Assurance Contract Expiration Date 01/16/2024 Installation Instructions FL22382_R3_II_NL-0091_Rev2_Fixed_Ventana_ss.pdf Verified By: Robert J Amoruso, P.E. FL PE License 49752 Created by Independent Third Party: Yes Evaluation Reports FL22382_R3_AE_PER-ACE-1047_Rev3_Fixed_Ventana_ss.pdf Created by Independent Third Party: Yes |
|
|
| 22382.2 |
Series 4760 Picture Window |
Series 4760 Picture Window, Non-Impact, HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +80/-80 Other: |
Certification Agency Certificate FL22382_R3_C_CAC_10-124_C1R0.pdf Quality Assurance Contract Expiration Date 01/16/2024 Installation Instructions FL22382_R3_II_NL-0091_Rev2_Fixed_Ventana_ss.pdf Verified By: Robert J Amoruso, P.E. FL PE License 49752 Created by Independent Third Party: Yes Evaluation Reports FL22382_R3_AE_PER-ACE-1047_Rev3_Fixed_Ventana_ss.pdf Created by Independent Third Party: Yes |
|
|
| 22382.3 |
Series 4760 Picture Window |
Series 4760 Picture Window, L.M. Impact, Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL22382_R3_C_CAC_10-125_C1R0.pdf FL22382_R3_C_CAC_10-202_C1R0.pdf Quality Assurance Contract Expiration Date 01/16/2024 Installation Instructions FL22382_R3_II_NL-0091_Rev2_Fixed_Ventana_ss.pdf Verified By: Robert J Amoruso, P.E. FL PE License 49752 Created by Independent Third Party: Yes Evaluation Reports FL22382_R3_AE_PER-ACE-1047_Rev3_Fixed_Ventana_ss.pdf Created by Independent Third Party: Yes |
|
|
| 22382.4 |
Series 4760 Picture Window |
Series 4760 Picture Window, Non-Impact, Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +80/-80 Other: |
Certification Agency Certificate FL22382_R3_C_CAC_10-126_C1R0.pdf Quality Assurance Contract Expiration Date 01/16/2024 Installation Instructions FL22382_R3_II_NL-0091_Rev2_Fixed_Ventana_ss.pdf Verified By: Robert J Amoruso, P.E. FL PE License 49752 Created by Independent Third Party: Yes Evaluation Reports FL22382_R3_AE_PER-ACE-1047_Rev3_Fixed_Ventana_ss.pdf Created by Independent Third Party: Yes |