FL # FL9798-R9
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Flex Membrane International Corp.
Address/Phone/Email 5103A Pottsville Pike
Reading, PA 19605
(610) 916-9500
mikeg@flexmembranes.com
 
Authorized Signature Michael Giangiacomo
mikeg@flexmembranes.com
 
Technical Representative John Doyle
Address/Phone/Email 200 Bethlehem Drive
Morgantown, PA 19543
jdoyle@flex.com
 
Quality Assurance Representative Mike Giangiacomo
Address/Phone/Email 200 Bethlehem Drive
Morgantown, PA 19543
mgiangiacomo@flex.com
 
Category Roofing
Subcategory Single Ply Roof Systems
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 06/16/2029
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL9798_R9_COI_2023_07_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D68782021
ASTM G1552013
FM 44702016
FM 44742011
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/29/2023
Date Validated 09/08/2023
Date Pending FBC Approval 09/14/2023
Date Approved 12/12/2023
Date Revised 09/30/2026
 
Summary of Products
FL # Model, Number or Name Description
9798.1 Flex TPO Plus Single Ply Roof Systems TPO Single Ply Roof Systems
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-232.5
 Other: 1.) The design pressure noted in this application relates to one specific system. Refer to ER Appendix for other system and deck types. 2.) Refer to ER Section 5 for Limits of Use.
Installation Instructions
 FL9798_R9_II_2023_08_29_FINAL_A1_PEER-FMI-002.A_TPO PLUS_FL9798-R9.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9798_R9_AE_2023_08_29_FINAL_PEER-FMI-002.A_TPO PLUS_FL9798-R9.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 