Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL42139-R2
Application Type Revision
Code Version 2026
Application Status Pending FBC Approval
 
Comments
Archived
 
Product Manufacturer Advanced Hurricane Technology Inc.
Address/Phone/Email 6063 Janes Lane
Naples, FL 34109
(239) 594-7722
jzabala@aol.com
 
Authorized Signature Jaime Zabala
jzabala@aol.com
 
Technical Representative Dave Finnegan
Address/Phone/Email 6063 Janes Lane
Naples, FL 34109
(239) 594-7722
Finnegan1of10@aol.com
 
Quality Assurance Representative National Accreditation and Management Inc.
Address/Phone/Email 4655-104 Monticello Ave.
Williamsburg, VA 23188
(757) 258-8808
namicertification@nami.hrcoxmail.com
 
Category Impact Protective Systems
Subcategory Operable
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report WALTER A. TILLIT JR., P.E.
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2027
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL42139_R2_COI_COI Drwg 26-270 Advanced Hurricane Technology.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/28/2026
Date Validated 09/28/2026
Date Pending FBC Approval 10/06/2026
 
Summary of Products
FL # Model, Number or Name Description
42139.1 IMPACT PROTECTIVE ROLLING SYSTEM WITH CHD-6 SLAT (END RETENTION) (HVHZ) Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: No
 Impact Resistant: Yes
 Design Pressure: +30/-30
 Other: LARGE MISSILE (BASIC PROTECTION ONLY). PRESSURE RATING +30, -30 P.S.F. AT 21' - 8" SPAN (WALL MOUNTED) AND +140, - 140 P.S.F. AT 7' - 9" (WALL MOUNTED) SPAN, 3/8" SLIP. SEE SHEETS 13 AND 18 OF INSTALLATION DRAWING FOR ADDITIONAL PRESSURES AND SPANS.
Installation Instructions
 FL42139_R2_II_PED Drwg 26-270 Advanced Hurricane Technology.pdf
 Verified By: WALTER A. TILLIT JR., P.E. PE-44167
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42139_R2_AE_PER Drwg 26-270 Advanced Hurricane Technology.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824