| 42140.1 |
ROLL UP SHUTTER SYSTEM WITH CHD-6 SLAT (END RETENTION) (NHVHZ) |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +30/-30 Other: LARGE MISSILE LEVEL "D", WIND ZONES 1,2,3 AND 4 (BASIC PROTECTION ONLY). PRESSURE RATING +30, -30 P.S.F. AT 21' -8" SPAN (WALL MOUNTED) AND +140, -140 P.S.F. AT 7' -9" (WALL MOUNTED) SPAN, 3/8" SLIP. SEE SHEETS 13 AND 18 OF INSTALLATION DRAWING FOR ADDITIONAL PRESSURES AND SPANS. |
Installation Instructions FL42140_R2_II_PED Drwg 26-269 Advanced Hurricane Technology.pdf Verified By: WALTER A. TILLIT JR., P.E. PE-44167 Created by Independent Third Party: Yes Evaluation Reports FL42140_R2_AE_PER Drwg 26-269 Advanced Hurricane Technology.pdf Created by Independent Third Party: Yes |