| 31995.1 |
1618 SGD |
144x96 XXX Finless Frame |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: LC-PG50, Missile Level D, Wind Zone 3. Glass shall be 5/32" tempered, aluminum box spacer, 1/4" annealed/0.090" PVB/ 1/4" thick annealed. Glass shall be bedded in Pecora 896 sealant with a glazing bite of 1/2". |
Certification Agency Certificate FL31995_R2_C_CAC_APC(20482)11714.02-106-11-R2,11714.01-106-11-R2_1618 SGD(081927).pdf Quality Assurance Contract Expiration Date 08/09/2027 Installation Instructions FL31995_R2_II_27488.12-1001 - 1618 SGD XXX 144x96 Impact.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL31995_R2_AE_27488.12-107-16-R0 - MI Windows and Doors 1618 SGD XXX - Impact.pdf Created by Independent Third Party: Yes |
|
|
| 31995.2 |
1618 SGD |
144x96 XXX Finless Frame |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: LC-PG50. Product shall be glazed per ASTM E1300 w/safety glazing. |
Certification Agency Certificate FL31995_R2_C_CAC_APC(20481)11982.01-106-11-R0_1618 SGD(111627).pdf Quality Assurance Contract Expiration Date 11/16/2027 Installation Instructions FL31995_R2_II_27488.13-1001 - 1618 SGD XXX 144x96 non-Impact.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL31995_R2_AE_27488.13-107-16 - MI Windows and Doors - 1618 non-Impact XXX 144x96 SGD.pdf Created by Independent Third Party: Yes |
|
|
| 31995.3 |
1618 SGD |
144x96 Fin and Finless Frame, no sill extender. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-50 Other: LC-PG35. Product shall be glazed per ASTM E1300 with (exterior to interior) 5/32" tempered - spacer - 1/8" annealed / 0.100" SGP / 1/8" annealed. |
Certification Agency Certificate FL31995_R2_C_CAC_APC(18522)2081.03-106-12-R0_1618 SGD(090624).pdf Quality Assurance Contract Expiration Date 09/06/2024 Installation Instructions FL31995_R2_II_27488.02-1002 1618 non-Impact SGD 144x96.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL31995_R2_AE_27488.02b-107-16 - MI Windows 1618 SGD Finless at Sill.pdf Created by Independent Third Party: Yes |
|
|
| 31995.4 |
1618 SGD |
144x96 Fin Frame Impact XXO |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: LC-PG 50. Missile Level D, Wind Zone 3. Glazing: Exterior to Interior - 5/32" tempered, aluminum box spacer, 1/8" annealed - 0.100" SGP - 1/8" annealed. Glass bite is 1/2" and glass is bedded in Pecora 896 silicone. |
Certification Agency Certificate FL31995_R2_C_CAC_APC(18523)2081.03-106-12-R0_1618 SGD(090624).pdf Quality Assurance Contract Expiration Date 09/06/2024 Installation Instructions FL31995_R2_II_27488.02-1003 1618 Impact SGD 144x96.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL31995_R2_AE_27488.02b-107-16 - MI Windows 1618 SGD Finless at Sill.pdf Created by Independent Third Party: Yes |
|
|
| 31995.5 |
1618 SGD |
140x96 Fin and Finless Frame w/sill extender |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: LC-PG30. Product shall be glazed per ASTM E1300 with safety glazing. |
Certification Agency Certificate FL31995_R2_C_CAC_APC(18524)2081.02-106-12-R0_1618 SGD(090624).pdf Quality Assurance Contract Expiration Date 09/06/2024 Installation Instructions FL31995_R2_II_27488.02-1001 1618 non-Impact SGD 140x96.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL31995_R2_AE_27488.02b-107-16 - MI Windows 1618 SGD Finless at Sill.pdf Created by Independent Third Party: Yes |
|
|
| 31995.6 |
1618 SGD |
144x96 Fin and Finless Frame, w/sill extender |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: LC-PG50. Product shall be glazed per ASTM E1300 with (exterior to interior) 5/32" tempered - spacer - 1/8" annealed / 0.100" SGP / 1/8" annealed. |
Certification Agency Certificate FL31995_R2_C_CAC_APC(18525)2081.03-106-12-R0_1618 SGD(090624).pdf Quality Assurance Contract Expiration Date 09/06/2024 Installation Instructions FL31995_R2_II_27488.02-1002 1618 non-Impact SGD 144x96.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL31995_R2_AE_27488.02b-107-16 - MI Windows 1618 SGD Finless at Sill.pdf Created by Independent Third Party: Yes |