| 31282.1 |
26GA PBR PANEL |
36" WIDE PANEL OVER 15/32" APA PLYWOOD FOR NON-HVHZ; 19/32" APA PLYWOOD FOR HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.75 Other: -154.75PSF 7"-5"-7"-5" @12"O.C.
-60.5PSF 12"-12"-12" @ 24" O.C.
INSTALL PER MANUFACTURERS INSTALL DETAILS. |
Installation Instructions FL31282_R2_II_SS 2023 FL 31282 REPORTS AND DETAILS.pdf Verified By: LOCKE BOWDEN, P.E. FL 49704 Created by Independent Third Party: Yes Evaluation Reports FL31282_R2_AE_SS 2023 FL 31282 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 31282.2 |
26GA RIB PANEL |
36" WIDE RIB PANEL OVER APA 15/32" PLYWOOD NON-HVHZ, 19/32" PLYWOOD HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.25 Other: -159.25PSF FASTENING 6.5-2.5-6.5-2.5-6.5-2.5 @12" O.C.
-71.75PSF FASTENING 9"-9"-9"-9"
@24" O.C. INSTALL PER MANUFACTURER'S DETAILS |
Installation Instructions FL31282_R2_II_SS 2023 FL 31282 REPORTS AND DETAILS.pdf Verified By: LOCKE BOWDEN, P.E. FL 49704 Created by Independent Third Party: Yes Evaluation Reports FL31282_R2_AE_SS 2023 FL 31282 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 31282.3 |
29GA RIB PANEL |
36" WIDE RIB OVER APA 15/32" PLYWOOD-NON-HVHZ
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-71.0 Other: -71.0PSF FASTENING 9"-9"-9"
@24" O.C.
-108PSF FASTENING 6.5PSF-2.5PSF-6.5PSF-2.5PSF=6.5PSF-2.5PSF @24" O.C. INSTALL PER MANUFACTURER'S DETAILS
INSTALL PER MANUFACTURERS DETAILS. NOT FOR USE IN HVHZ ZONE. |
Installation Instructions FL31282_R2_II_SS 2023 FL 31282 REPORTS AND DETAILS.pdf Verified By: LOCKE BOWDEN, P.E. FL 49704 Created by Independent Third Party: Yes Evaluation Reports FL31282_R2_AE_SS 2023 FL 31282 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |