Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL7396-R9
Application Type Revision
Code Version 2026
Application Status Applied For
 
Comments
Archived
 
Product Manufacturer ACI Building Systems, LLC
Address/Phone/Email 10125 Highway 6 West
PO Box 1316
Batesville, MS 38606
(662) 563-4574
keith.shedd@acibuildingsystems.com
 
Authorized Signature Keith Shedd
keith.shedd@acibuildingsystems.com
 
Technical Representative Keith Shedd
Address/Phone/Email ACI Building Systems
PO Box 1316
Batesville, MS 38606
(662) 563-4574
keith.shedd@acibuildingsystems.com
 
Quality Assurance Representative Jeremy Cedotal
Address/Phone/Email ACI Building Systems
PO Box 1316
Batesville, MS 38606
(662) 563-4574   Ext 295
jeremy.cedotal@acibuildingsystems.com
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 12/31/2029
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL7396_R9_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AISI S1002020
ASTM E15922017
FM 44702022
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/15/2026
Date Validated
 
Summary of Products
FL # Model, Number or Name Description
7396.1 PBM Panel Min. 26 ga., 36" wide, through fastened panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-118.9
 Other: Uplift load of 118.9 psf at support spacing of 24" o.c.
Installation Instructions
 FL7396_R9_II_EvaluationReportC3089_1.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7396_R9_AE_EvaluationReportC3089_1.pdf
 Created by Independent Third Party: Yes
7396.2 PBR Panel Min. 26 ga., 36" wide, through fastened panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-193.8
 Other: Uplift load of 193.8 psf at support spacing of 24" o.c. for Fastener Pattern 2.
Installation Instructions
 FL7396_R9_II_EvaluationReportC3089_2.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7396_R9_AE_EvaluationReportC3089_2.pdf
 Created by Independent Third Party: Yes
7396.3 StratoShield Min 24 ga., 24" wide standing seam roof panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-183.3
 Other: Maximum uplift load of 183.3 psf @ support spacing of 24" o.c. with BA Series clips and QuadLok seam
Installation Instructions
 FL7396_R9_II_EvaluationReportC3089_3.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7396_R9_AE_EvaluationReportC3089_3.pdf
 Created by Independent Third Party: Yes
7396.4 Ultralok 216 & 218 Min 24 ga., max 18" wide standing seam panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-235
 Other: Maximum uplift load of 235 psf at support spacing of 24" o.c. with MPS 1200 Series clips and QuadLok seam
Installation Instructions
 FL7396_R9_II_EvaluationReportC3089_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7396_R9_AE_EvaluationReportC3089_4.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex