Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Proposed Code Modifications Proposed Code Modifications
USER: Public User
 
 
Jump to Bottom
SW7070
Jennifer Hatfield
411 Lenore Court
Rockledge
FL
32955
jen@jhatfieldandassociates.com
(941) 345-3263
 
Verified
Swimming Pool
Approved as Modified
Approved as Modified
No

2017
2017 Triennial Original Modification 07/01/2015 - 01/03/2016
Building
Chapter 4 - Special Detailed Requirements Based on Use and Occupancy
454.1.10.1
No
Reinstates language from the 2010 Code that was not included in the 5th edition. This is needed to ensure certain safety aspects are addressed when resurfacing a public swimming pool.

454.1.10.1 Modifications. Modifications include nonequivalent changes or additions to the recirculation system, treatment equipment, physical structure or appurtenances. Replacement of the pool or spa shell is considered to be construction of a new facility and shall be processed as such. The installation of new decking is not considered a modification if it is installed in conformance with Section 454.1.3.1, and deck markings are upgraded in accordance with Section 454.1.2.3. Resurfacing the pool interior to original nontoxic, slip-resistant and smooth specifications or equivalent replacement of equipment are not considered modifications. However, the following items shall be addressed during resurfacing projects:

454.1.10.1.1 The lip of the gutter must be leveled to within 1/4 inch (6.4 mm) between the highest and lowest point and the downward slope from the lip to the drain must be maintained as originally designed or increased, but shall not exceed new construction standards.

454.1.10.1.2 Tile step markings must be installed meeting the requirements of Section 454.1.2.5.3.

454.1.10.1.3 Where applicable the slope break marking must be installed meeting the requirements of Section 454.1.2.2.3.2 and safety line must be installed 2 feet (610 mm) before the marking.

454.1.10.1.4 Depth markers and NO DIVING markers must be installed in accordance with Section 454.1.2.3.

454.1.10.1.5 The pool ladder must have a 3 to 6 inch (76 to 152 mm) clearance from the pool wall. New cross-braced ladder(s) shall be installed in place of non cross-braced ladder(s) in conformance with Section 454.1.2.5.1 during a pool resurfacing.

454.1.10.1.6 Should resurfacing works affect the step riser heights, no riser shall exceed 12 inches (305 mm) and the intermediate risers shall be made uniform.

454.1.10.1.7 Recessed treads that protrude from the pool wall shall be removed and replaced with a cross-braced ladder or reconstructed to meet the requirements of Section 454.1.2.5.2.

 
DateAttached File
01/19/2016 Mod_7070_TextOfModification.pdf
 


 
 
 
 

 
 
 


 
 
 
 
 
 
 
 
 
 
 
 
01/01/2016
01/02/2016
04/05/2016
08/24/2016

Mod #StageDate SubmittedSubmitted ByCode Change Cycle
SW7070-A1 Alternate Language 02/25/2016  Jennifer Hatfield  2017 Triennial First Comment Period 01/11/2016 - 02/25/2016 
SW7070-R1 Revision 04/05/2016  Joe Bigelow   
SW7070-A3 Alternate Language 06/21/2016  Jennifer Hatfield  2017 Triennial Second Comment Period 05/06/2016 - 06/21/2016 
SW7070-R2 Revision 08/29/2016  Joe Bigelow   
 