Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL7271-R3
Application Type Revision
Code Version 2014
Application Status Approved
 
Comments
Archived
 
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 813-2432
rblake@unioncorrugating.com
 
Authorized Signature Randy Blake
rblake@unioncorrugating.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL7271_R3_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922001
FM 44701992
UL 18971998
UL 18972004
UL 5801994
UL 5802006
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL7271_R3_Equiv_TestEquivalent_7271_UL.pdf
FL7271_R3_Equiv_TestEquivalent_C1999_19.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 03/23/2015
Date Validated 04/08/2015
Date Pending FBC Approval 04/13/2015
Date Approved 06/23/2015
Date Revised 08/23/2017
 
Summary of Products
FL # Model, Number or Name Description
7271.1 2-1/2" Corrugated Panel Min 26 ga., 24" wide through fastened panel with coverage width of 21-1/4"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-129.25
 Other: Uplift load of 129.25 psf @ fastener spacing of 24" o.c. over 19/32" thick plywood
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_9.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_9.pdf
 Created by Independent Third Party: Yes
7271.2 5V Min 26 ga., 24" wide through fastened panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-66.3
 Other: Uplift load of 66.3 psf @ fastener spacing of 12" o.c.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_10.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_10.pdf
 Created by Independent Third Party: Yes
7271.3 5V Min 29 ga., 24" wide through fastened panel over 15/32" thick plywood or 7/16" thick OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of 52.5 psf @ fastener spacing of 12" o.c.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_11.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_11.pdf
 Created by Independent Third Party: Yes
7271.4 5V Min 26 ga., 24" wide through fastened panel over 19/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-120.9
 Other: Uplift load of 120.9 psf @ fastener spacing of 24" o.c. for Fastener Pattern 1. Uplift load of 85.8 psf @ fastener spacing of 24" o.c. and 113.1 psf @ fastener spacing of 12" o.c. for Fastener Pattern 2.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_12.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_12.pdf
 Created by Independent Third Party: Yes
7271.5 5V Min 26 ga., 24" wide through fastened panel over 15/32" or 19/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-150
 Other: Uplift load of 150 psf in 19/32" thick plywood for Fastener Pattern 2
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_13.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_13.pdf
 Created by Independent Third Party: Yes
7271.6 Advantage-Lok II Min 26 ga., 16" wide concealed fastened panel over 7/16" thick OSB & 15/32" & thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-112.5
 Other: Uplift load of 52.5 psf @ fastener spacing of 6" o.c. and uplift load of 112.5 psf @ fastener spacing of 6" o.c. with structural sealant.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_14.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_14.pdf
 Created by Independent Third Party: Yes
7271.7 Advantage-Lok II Min 26 ga., 16" wide concealed fastened panel over 15/32" & 19/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-107.9
 Other: Uplift load of 59.4 psf @ fastener spacing of 6" o.c. in 15/32" plywood. Uplift load of 97.5 psf @ fastener spacing of 6" o.c. with structural sealant in 15/32" plywood. Uplift load of 107.9 psf @ fastener spacing of 4" o.c. with structural sealant in 19/32" plywood.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_15.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_15.pdf
 Created by Independent Third Party: Yes
7271.8 MasterRib Min 26 ga., 36" wide through fastened panel over 19/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-114.3
 Other: Uplift load of 61.8 psf @ fastener spacing of 30" o.c. and 114.3 psf @ fastener spacing of 24" o.c.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_16.pdf
 Verified By: Bala Sockalingam 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_16.pdf
 Created by Independent Third Party: Yes
7271.9 MasterRib Min 29 ga., 36" wide through fastened panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-113.1
 Other: Uplift load of 45.0 psf @ fastener spacing of 24" o.c. & 113.1 psf @ fastener spacing of 12" o.c.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_17.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_17.pdf
 Created by Independent Third Party: Yes
7271.10 MasterRib Min 29 ga., 36" wide through fastened panel over 15/32" thick plywood or 7/16" thick OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of 52.5 psf @ fastener spacing of 12" o.c.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_18.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_18.pdf
 Created by Independent Third Party: Yes
7271.11 MasterRib Min 29 ga., 36" wide through fastened panel over nom. 1" x 4" furring and 15/32" thick plywood or 7/16" thick OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-114
 Other: Uplift load of 71 psf for Fastener Pattern 1 & 114 psf for Fastener Pattern 2
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_19.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_19.pdf
 Created by Independent Third Party: Yes
7271.12 ML200 Min 24 ga., max 16" wide standing seam metal panel with double lock seam over metal deck.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0
 Other: Uplift load of 71.0 psf @ clip spacing of 36" o.c. and 116.0 psf @ clip spacing of 12" o.c.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_20.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_20.pdf
 Created by Independent Third Party: Yes
7271.13 PBR Min 26 ga., 36" wide through fastened panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of 52.5 psf @ fastener spacing of 12" o.c.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_21.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_21.pdf
 Created by Independent Third Party: Yes
7271.14 SL175 Min 24 ga., max 16" wide snap-lock standing seam metal panel over metal deck.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-86.0
 Other: Uplift load of 63.5 psf @ clip spacing of 36" o.c. and 86.0 psf @ clip spacing of 12" o.c.
Installation Instructions
 FL7271_R3_II_EvaluationReportC1999_22.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R3_AE_EvaluationReportC1999_22.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe