389.1 |
Bertha HV Accordion Shutter - Blade 3 - (Non-HVHZ) - Drwg 11-190 |
Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile Level "D". Max span is 13'-0" for 40 p.s.f. ASD negative load the HV3 blade w/o window blade, 5'-6" for 110 p.s.f ASD load for HV3 blade w/o window blade and 9'-6" for 62 p.s.f for HV3 blade w/ window blade working in unison and 84" for 72 p.s.f. ASD load for HV3 blade w/o window blade installed into metal studs. See sheet number 5 of installation drawings for other spans and pressures. |
Installation Instructions FL389_R5_II_drwg 11-190 ASSA.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL389_R5_AE_product evaluation drwg 11-190.pdf Created by Independent Third Party: Yes |
|
389.2 |
Bertha HV Accordion Shutter-Blade 1 Only- (Non-HVHZ)- Drwg 11-192 |
Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile level “D”. Max. Span is 16’-0” for 30 p.s.f negative ASD load depending on centermates and locking rod configuration for the HV1 blade, 8’-0” for +64, -72 p.s.f. load for HV blade for Keystone mountings 7’-0” for +75, -75 p.s.f. for metals stud mountings and 8’-0” for 110 p.s.f. for HV1 and HV1A working in unison. See sheets 7, 11 and 20 respectively of installation drawings for other spans and pressures. |
Installation Instructions FL389_R5_II_ASSA drwg 11-192.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL389_R5_AE_ASSA_Productevaluationreportdrwg11192.pdf Created by Independent Third Party: Yes |
|
389.3 |
Bertha HV Accordion Shutter-COMBO- (Non-HVHZ)- Drwg 11-194 |
Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile. Max. 16’-0” span at 30 p.s.f ASD load for Blade 1 and 18’-0” for Blade 2. See schedules on sheet 12, 25 and 28 respectively |
Installation Instructions FL389_R5_II_ASSA_DRWG 11-194.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL389_R5_AE_ASSA_Product evaluation report drwg 11-194.pdf Created by Independent Third Party: Yes |