18375.1 |
Insulated Rolling Door - HVHZ |
12'-5" wide x 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Up to 50 FPS Impact Resistance |
Installation Instructions FL18375_R2_II_20-0416_07.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL18375_R2_AE_20-0416_07.pdf |
|
18375.2 |
Insulated Rolling Door - HVHZ |
12'-5" wide x 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Up to 80 FPS Impact Resistance |
Installation Instructions FL18375_R2_II_20-0416_13.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL18375_R2_AE_20-0416_13.pdf |
|
18375.3 |
Insulated Rolling Door - HVHZ |
14'-5" wide x 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Up to 80 FPS Impact Resistance |
Installation Instructions FL18375_R2_II_20-0416_10.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL18375_R2_AE_20-0416_10.pdf |
|
18375.4 |
Insulated Rolling Door - HVHZ |
25'-5" wide x 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Up to 80 FPS Impact Resistance |
Installation Instructions FL18375_R2_II_20-0416_11.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL18375_R2_AE_20-0416_11.pdf |
|
18375.5 |
Non-Insulated Rolling Door - HVHZ |
14'-5" wide x 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Up to 50 FPS Impact Resistance |
Installation Instructions FL18375_R2_II_20-0416_09.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL18375_R2_AE_20-0416_09.pdf |
|
18375.6 |
Non-Insulated Rolling Door - HVHZ |
14'-5" wide x 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Up to 80 FPS Impact Resistance |
Installation Instructions FL18375_R2_II_20-0416_08.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL18375_R2_AE_20-0416_08.pdf |
|
18375.7 |
Non-Insulated Rolling Door - HVHZ |
25'-5" wide x 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Up to 80 FPS Impact Resistance |
Installation Instructions FL18375_R2_II_20-0416_12.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL18375_R2_AE_20-0416_12.pdf |
|
18375.8 |
Non-Insulated Rolling Door - HVHZ |
27'-5" wide x 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Up to 50 FPS Impact Resistance |
Installation Instructions FL18375_R2_II_20-0416_14.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL18375_R2_AE_20-0416_14.pdf |