Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL11560-R2
Application Type Revision
Code Version 2014
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email 7800 Highway 60
Sellersburg, IN 47172
(502) 855-4300
dstermer@metalsales.us.com
 
Authorized Signature David Stermer
dstermer@metalsales.us.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL11560_R2_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 1252003
UL 18971998
UL 18972004
UL 5802006
UL 5801994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL11560_R2_Equiv_TestEquivalentC2009_2_3_12.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 03/31/2015
Date Validated 04/07/2015
Date Pending FBC Approval 04/12/2015
Date Approved 06/22/2015
Date Revised 09/09/2017
 
Summary of Products
FL # Model, Number or Name Description
11560.1 Aluminum 5V-Crimp 24" wide, nom 0.032" thick (min.) aluminum through fastened roof panel over min 15/32” thick plywood deck or 7/16" thick OSB with fasteners through panel rib.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-161.5
 Other: Uplift load of 30 psf at fastener spacing of 36" o.c. and 161.5 psf at fastener spacing of 6" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_1.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_1.pdf
 Created by Independent Third Party: Yes
11560.2 Aluminum Image II 16" wide, nom 0.032" thick (min.) aluminum concealed fastener roof panel over min 15/32” thick plywood deck or 7/16" thick OSB.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-107.35
 Other: Uplift load of 22.5 psf at fastener spacing of 24" o.c. and 107.35 psf at fastener spacing of 6" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_2.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_2.pdf
 Created by Independent Third Party: Yes
11560.3 Aluminum Image II 16" wide, nom 0.032" thick (min.) aluminum concealed fastener roof panel over min 19/32” thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-195.0
 Other: Uplift load of 22.5 psf at fastener spacing of 24" o.c., 104.7 psf at fastener spacing of 6" o.c. and 195.0 psf at fastener spacing of 6" o.c. with support strap.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_3.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_3.pdf
 Created by Independent Third Party: Yes
11560.4 Image II Min. 26 ga., max. 16" wide standing seam roof panel over min. 15/32” thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-84.25
 Other: Uplift load of 84.25 psf at fastener spacing of 24" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_4.pdf
 Created by Independent Third Party: Yes
11560.5 Image II Min. 26 ga., max. 16" wide standing seam roof panel over min. 19/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-139.1
 Other: Uplift load of 84.25 psf @ fastener spacing of 24", 102.7 psf @ fastener spacing of 6" and 139.1 psf @ fastener spacing of 6" with 3/8" bead adhesive in sidelap
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_5.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_5.pdf
 Created by Independent Third Party: Yes
11560.6 Magna-Loc Min. 24 ga., 16" wide standing seam roof panel over plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-166.0
 Other: Uplift load of 95.2 psf @ MC clip spacing of 30" o.c., 101.0 psf @ MC clip spacing of 15" o.c., 123.5 psf @ MC clip spacing of 8" o.c. and 166 psf @ MPW clip spacing of 12" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_6.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_6.pdf
 Created by Independent Third Party: Yes
11560.7 Magna-Loc Min. 24 ga., 16" wide standing seam roof panel over steel deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-168.5
 Other: Uplift load of 59.7 psf @ MC clip spacing of 36" o.c. and 168.5 psf @ MPW clip spacing of 12" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_7.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_7.pdf
 Created by Independent Third Party: Yes
11560.8 Stile Min. 26 ga., 39.4" wide through fastened roof panel over min. 15/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-102.7
 Other: Uplift load of 85.8 psf at fastener spacing of 24" o.c. and 102.7 psf at fastener spacing of 12" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_8.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_8.pdf
 Created by Independent Third Party: Yes
11560.9 Stile Min. 26 ga., 39.4" wide through fastened roof panel over min. 19/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-149.6
 Other: Uplift load of 50.4 psf at fastener spacing of 36" o.c., 106.8 psf at fastener spacing of 24" o.c. and 149.6 psf at fastener spacing of 12" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_9.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_9.pdf
 Created by Independent Third Party: Yes
11560.10 Vertical Seam Min 24 ga., max. 16" wide standing seam roof panel over min. 15/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-114.25
 Other: Uplift load of 30.0 psf at clip spacing of 48" o.c., 73.0 psf at clip spacing of 24" o.c. and 114.25 psf at clip spacing of 8" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_10.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_10.pdf
 Created by Independent Third Party: Yes
11560.11 Vertical Seam Min 24 ga., max. 18" wide standing seam roof panel over min. 15/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-105
 Other: Uplift load of 30.0 psf at clip spacing of 48" o.c., 82.5 psf at clip spacing of 12" o.c. and 105.0 psf at clip spacing of 12" o.c. with sidelap adhesive.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_11.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_11.pdf
 Created by Independent Third Party: Yes
11560.12 Vertical Seam Min. 26 ga., 16" wide standing seam roof panel over min. 15/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-81.3
 Other: Uplift load of 30.0 psf at clip spacing of 48" o.c. and 81.3 psf at clip spacing of 6" o.c.
Installation Instructions
 FL11560_R2_II_EvaluationReportC2009_12.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11560_R2_AE_EvaluationReportC2009_12.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe