Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL6393-R12
Application Type Affirmation
Code Version 2017
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648
(864) 377-0691
Mike.rhoden@velux.com
 
Authorized Signature Roger LeBrun
roger.lebrun@velux.com
 
Technical Representative Roger LeBrun
Address/Phone/Email 1418 Evans Pond Road
Greenwood, SC 29649-8725
(864) 941-4828
roger.lebrun@velux.com
 
Quality Assurance Representative Mike Dorn
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648-5001
(864) 941-4700
mike.dorn@velux.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA 101/I.S.2/A4402011
ASTM E18862005
ASTM E19962005
 
Equivalence of Product Standards
Certified By

 
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 08/02/2017
Date Validated 08/02/2017
Date Pending FBC Approval
Date Approved 08/10/2017
Date Revised 11/02/2018
 
Summary of Products
FL # Model, Number or Name Description
6393.1 VELUX SUN TUNNEL™ TSR 0000 TSR 010 size (426-H-626.07)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +200/-180
 Other: TDDCC-PG180; Size tested 254 mm dia (10 in). PG180 means minimum capacity is 180 psf. Dome glazing is minimum 3mm thick. Flashing nails directly to roof deck. Anchorage fasteners provided are 10 ga. galv. ring shank nails.
Certification Agency Certificate
 FL6393_R12_C_CAC_TSR acr - CCL for VELUX 4-25-17.pdf
Quality Assurance Contract Expiration Date
 04/03/2027
Installation Instructions
 FL6393_R12_II_TSR Hallmark Supplemental Instr.pdf
 FL6393_R12_II_TSR_installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.2 VELUX SUN TUNNEL™ (14" Commercial) Impact Resistant [TCC, TMC or TGC] + 014 + [100*TH or THE0, 100*TO or TOE0, 100*TT or TTE0], where * denotes diffuser 0, 2 or 3 (426-H-707.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 356 mm (14 in). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R12_C_CAC_14 inch Commercial SUN TUNNEL - Impact.pdf
Quality Assurance Contract Expiration Date
 11/29/2021
Installation Instructions
 FL6393_R12_II_453581-2013-12-TCC.pdf
 FL6393_R12_II_453607-2013-10_TGC-TMC.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.3 VELUX SUN TUNNEL™ (14" Commercial) Non-Impact [TCC, TMC or TGC] + 014 + [000*TH or THE0, 000*TO or TOE0, 000*TT or TTE0, 100*TH or THE0, 100*TO or TOE0, 100*TT or TTE0], where * denotes diffuser 0, 2 or 3 (426-H-707.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +300/-150
 Other: TDDCC/TDDOC-PG150; Max. dia. 356 mm (14 in). PG150 means minimum capacity is 150 psf. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R12_C_CAC_14 inch Commercial SUN TUNNEL - NAFS-11.pdf
Quality Assurance Contract Expiration Date
 12/14/2021
Installation Instructions
 FL6393_R12_II_453581-2013-12-TCC.pdf
 FL6393_R12_II_453607-2013-10_TGC-TMC.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.4 VELUX SUN TUNNEL™ (22" Commercial) Impact Resistant [TCC or TGC] + 022 + [500*TH or THE0, 500*TO or TOE0, 500*TT or TTE0], where * denotes diffuser 0, 2 or 3 (426-H-708.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 559 mm (22 in). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R12_C_CAC_22 inch Commercial SUN TUNNEL - Impact.pdf
Quality Assurance Contract Expiration Date
 12/20/2021
Installation Instructions
 FL6393_R12_II_453581-2013-12-TCC.pdf
 FL6393_R12_II_453607-2013-10_TGC-TMC.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.5 VELUX SUN TUNNEL™ (22" Commercial) Non-Impact [TCC or TGC] + 022 + [300*TH or THE0, 300*TO or TOE0, 300*TT or TTE0, 500*TH or THE0, 500*TO or TOE0, 500*TT or TTE0] (426-H-708.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +300/-130
 Other: TDDCC/TDDOC-PG130; Max. dia. 559 mm (22 in). PG130 means minimum capacity is 130 psf. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R12_C_CAC_22 inch Commercial SUN TUNNEL - NAFS-11.pdf
Quality Assurance Contract Expiration Date
 12/20/2021
Installation Instructions
 FL6393_R12_II_453581-2013-12-TCC.pdf
 FL6393_R12_II_453607-2013-10_TGC-TMC.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.6 VELUX SUN TUNNEL™ (Residential Curb Mount) Impact Resistant TCR 014 + [1000US or 1000USE0] (426-H-706.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 356 mm (14 in). This model was tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing attaches to site-built curb. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R12_C_CAC_Curb Mount Residential SUN TUNNEL - Impact.pdf
Quality Assurance Contract Expiration Date
 10/30/2021
Installation Instructions
 FL6393_R12_II_453125-2013-10-TCR_014.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.7 VELUX SUN TUNNEL™ (Residential Curb Mount) Non-Impact TCR 014 + [0000US, 0000USE0, 1000US or 1000USE0] (426-H-706.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +300/-165
 Other: TDDCC-PG165; Dia. 356 mm (14 in.) PG165 means minimum capacity is 165 psf. Flashing attaches to site-built curb with eight supplied screws, two per side. Dome glazing is minimum 3mm thick.
Certification Agency Certificate
 FL6393_R12_C_CAC_Curb Mount Residential SUN TUNNEL - NAFS-11.pdf
Quality Assurance Contract Expiration Date
 11/21/2021
Installation Instructions
 FL6393_R12_II_453125-2013-10-TCR_014.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.8 VELUX SUN TUNNEL™ (Residential) Impact Resistant [TGF, TGR, TMF or TMR] + [010, 014 or 022] + [1000 or 1000E0] (426-H-705.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 559 mm (22 in.). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R12_C_CAC_Residential SUN TUNNEL - Impact.pdf
Quality Assurance Contract Expiration Date
 11/29/2021
Installation Instructions
 FL6393_R12_II_451635-2013-10-TGF-TMF.pdf
 FL6393_R12_II_451636-2013-09-TGR-TMR_Low.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.9 VELUX SUN TUNNEL™ (Residential) Non-Impact [TGF, TGR, TMF or TMR] + [010, 014 or 022] + [0000, 0000E0, 1000 or 1000E0] (426-H-705.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +300/-125
 Other: TDDCC-PG125; Max. dia. 559 mm (22 in.); PG125 means minimum capacity is 125 psf, uplift and download. Dome glazing is minimum 3 mm thick. Flashing types attach to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R12_C_CAC_Residential SUN TUNNEL - NAFS-11.pdf
Quality Assurance Contract Expiration Date
 12/18/2021
Installation Instructions
 FL6393_R12_II_451635-2013-10-TGF-TMF.pdf
 FL6393_R12_II_451636-2013-09-TGR-TMR_Low.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.10 VELUX SUN TUNNEL™ TLR (Tempered Glass) TLR 014 + [2000A or 2000AE1] (426-H-693.02)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +150/-245
 Other: TDDCC-PG150; Max. tube dia. 356 mm (14 in) - TDD. PG150 means minimum capacity is 150 psf. Exterior glazing is minimum 4mm thick clear tempered glass meeting ASTM E1300. Anchorage fasteners provided: 2.2 mm x 3/4" ring shank nails for alignment on top of roof deck, and #6 pan head sheet metal screws for clamping on underside of deck.
Certification Agency Certificate
 FL6393_R12_C_CAC_TLR 014 2000A or 2000AE1.pdf
Quality Assurance Contract Expiration Date
 10/03/2025
Installation Instructions
 FL6393_R12_II_453987-2015-06-TLR.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe