400.1 |
40mm & 60mm Bertha Roll Shutter (HVHZ) - Drawing Number 11-210 |
Aluminum Roll Shutter (Up or Down) Slats and supporting frame for storm protection |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. ASD Design Pressure rating: +40 p.s.f., -40 p.s.f. at 4'-2" span and +100 p.s.f., -100 p.s.f. at 2'-10" span (for 40mm slats), and +40, -40 p.s.f. at 6'-5" and +195, -195 p.s.f. at 3'-9" (for 60mm slats). See sheet 9 of installation drawing for additional spans and pressures. |
Installation Instructions FL400_R4_II_ASSA_DRWG. 11-210.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL400_R4_AE_ASSA_ Product Evaluation Report_drwg11-210.pdf Created by Independent Third Party: Yes |
|
400.2 |
40mm & 60mm Bertha Roll Shutter (Non-HVHZ) - Drawing Number 11-209 |
Aluminum Roll Shutter (Up or Down) Slats and supporting frame for storm protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. ASD Design Pressure rating: +25 p.s.f., -25 p.s.f. at 5'-2" span and +100 p.s.f., -100 p.s.f. at 2'-10" span (for 40mm slats), and +25, -25 p.s.f. at 7'-8" and +195, -195 p.s.f. at 3'-9" (for 60mm slats). See sheet 9 of installation drawing for additional spans and pressures. |
Installation Instructions FL400_R4_II_ASSA_ DRWG 11-209.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL400_R4_AE_ASSA_Product evaluation report 11-209.pdf Created by Independent Third Party: Yes |