11968.1 |
.050" Bertha Storm Panel (2 1/4" ) - Drawing Number 11-222 |
Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max Span is 12'-11" for +30, -30 p.s.f. ASD and 8'-2" for +75, -80 p.s.f. ASD for mountings without "H" header. See sheet 5 of installation drawings for other spans and pressures. |
Installation Instructions FL11968_R1_II_EASTERN METAL_DRWG 11-222.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R1_AE_EASTERN METAL_Product evaluation report drwg 11-222.pdf Created by Independent Third Party: Yes |
|
11968.2 |
0.040" Bertha Aluminum Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 11-224 |
Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 12'-0" for +25, -25 p.s.f. ASD and 4'-0" for +125, -130 p.s.f. ASD for sections 1, 3, 4, 6, 7, 8, 8A, 9 and 11. See sheet 10 of installation drawing for other spans and pressures. |
Installation Instructions FL11968_R1_II_EASTERN METAL_DRWG 11-224.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R1_AE_EASTERN METAL_Product evaluation report drwg 11-224.pdf Created by Independent Third Party: Yes |
|
11968.3 |
24 Gage Galvanized Bertha Steel Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 11-223 |
corrugated galvanized steel storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 9'-8" for +30, -40 p.s.f. ASD and 7'-2" for +70, -80 p.s.f. ASD for panels mounted without "H" header. See sheet 4 of installation drawing for other spans and pressures. |
Installation Instructions FL11968_R1_II_EASTERN METAL_DRWG 11-223.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R1_AE_EASTERN METAL_Product evaluation report drwg 11-223.pdf Created by Independent Third Party: Yes |
|
11968.4 |
Clear Bertha Storm Panels (2 1/4") - Drawing Number 11-220 |
Corrugated Polycarbonate Storm Panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 10'-0" for +28, -28 p.s.f ASD and 4'-0" for +105, -110 p.s.f ASD design load. See sheet 3 of installation drawings for other spans and pressures. |
Installation Instructions FL11968_R1_II_EASTERN METAL SUPPLY_DRWG 11-220.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R1_AE_EASTERN METAL SUPPLY_product evaluation report drwg 11-220.pdf Created by Independent Third Party: Yes |