Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL11968-R1
Application Type Revision
Code Version 2010
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Eastern Metal Supply
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(800) 432-2204
bfeeley@easternmetal.com
 
Authorized Signature Bill Feeley
bfeeley@easternmetal.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Shutters
Subcategory Storm Panels
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Walter A. Tillit, Jr.
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2015
Validated By John Henry Kampmann Jr.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL11968_R1_COI_EASTERN METAL_Certification of independence drwg 11-223.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E3302002
SSTD 12-991999
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/16/2011
Date Validated 12/21/2011
Date Pending FBC Approval 01/03/2012
Date Approved 01/31/2012
Date Revised 04/22/2015
 
Summary of Products
FL # Model, Number or Name Description
11968.1 .050" Bertha Storm Panel (2 1/4" ) - Drawing Number 11-222 Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large Missile. Max Span is 12'-11" for +30, -30 p.s.f. ASD and 8'-2" for +75, -80 p.s.f. ASD for mountings without "H" header. See sheet 5 of installation drawings for other spans and pressures.
Installation Instructions
 FL11968_R1_II_EASTERN METAL_DRWG 11-222.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11968_R1_AE_EASTERN METAL_Product evaluation report drwg 11-222.pdf
 Created by Independent Third Party: Yes
11968.2 0.040" Bertha Aluminum Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 11-224 Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large Missile. Max. span is 12'-0" for +25, -25 p.s.f. ASD and 4'-0" for +125, -130 p.s.f. ASD for sections 1, 3, 4, 6, 7, 8, 8A, 9 and 11. See sheet 10 of installation drawing for other spans and pressures.
Installation Instructions
 FL11968_R1_II_EASTERN METAL_DRWG 11-224.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11968_R1_AE_EASTERN METAL_Product evaluation report drwg 11-224.pdf
 Created by Independent Third Party: Yes
11968.3 24 Gage Galvanized Bertha Steel Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 11-223 corrugated galvanized steel storm panels retained or not by tracks to provide hurricane protection.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large Missile. Max. span is 9'-8" for +30, -40 p.s.f. ASD and 7'-2" for +70, -80 p.s.f. ASD for panels mounted without "H" header. See sheet 4 of installation drawing for other spans and pressures.
Installation Instructions
 FL11968_R1_II_EASTERN METAL_DRWG 11-223.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11968_R1_AE_EASTERN METAL_Product evaluation report drwg 11-223.pdf
 Created by Independent Third Party: Yes
11968.4 Clear Bertha Storm Panels (2 1/4") - Drawing Number 11-220 Corrugated Polycarbonate Storm Panels retained or not by tracks to provide hurricane protection.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large Missile. Max. span is 10'-0" for +28, -28 p.s.f ASD and 4'-0" for +105, -110 p.s.f ASD design load. See sheet 3 of installation drawings for other spans and pressures.
Installation Instructions
 FL11968_R1_II_EASTERN METAL SUPPLY_DRWG 11-220.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11968_R1_AE_EASTERN METAL SUPPLY_product evaluation report drwg 11-220.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe