11964.1 |
0.050" Bertha Aluminum Storm Panel (2 inch)- Drawing number 11-221 |
Corrugated aluminum Storm Panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile. Max. span is 13'-0" for +30, -30 p.s.f. ASD and 4'-0" for +90, -130 p.s.f. ASD for retained panels. See sheet 2 of installation drawing for other spans and pressures. |
Installation Instructions FL11964_R1_II_EASTERN METAL_ DRWG 11-221.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11964_R1_AE_EASTERN METAL_Product evlauation report drwg 11-221.pdf Created by Independent Third Party: Yes |
|
11964.2 |
24 Gage Bertha Galvanized Steel Panel (2 inch) - Drawing number 11-226 |
Corrugated steel storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 9'-10" for +32.6, -32.6 p.s.f. ASD and 2'-8" for +58.0, -58.0 p.s.f. ASD See sheet 2 of installation drawing number 08-149 for other spans and pressures. |
Installation Instructions FL11964_R1_II_EASTERN METAL_DRWG 11-226.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11964_R1_AE_EASTERN METAL_Product evaluation report drwg 11-226.pdf Created by Independent Third Party: Yes |