12725.1 |
26 Ga. Perma-Lok |
26 Ga. Perma-Lok over 15/32" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5PSF Other: -63.5 psf @ 5 3/16” O.C. fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL12725_R1_II_Perma-Lok_Detail.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL12725_R1_AE_Perma-Lok _load table.pdf FL12725_R1_AE_Perma-Lok 26 ga. over 15-32 Plywood Roof.pdf Created by Independent Third Party: Yes |
|
12725.2 |
26 Ga. Residential |
26 Ga. Residential over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -69.25 psf @ 24" o.c. fastener spacing. -146.0 psf @ 12" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL12725_R1_II_26 Ga. Residential over plywood detail.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL12725_R1_AE_26 Ga. Residential over plywood load table.pdf FL12725_R1_AE_26 Ga. Residential Panel over .5 Plywood NON Hvhz.pdf Created by Independent Third Party: Yes |
|
12725.3 |
26 Ga. Residential |
26 Ga. Residential over 1x4 Wood Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -109.25 psf @ 24" o.c. fastener spacing. -123.5 psf @ 24" o.c. fastener spacing. Install per manufacuturers details. Not for use in HVHZ Zones. |
Installation Instructions FL12725_R1_II_26 Ga. Residential over 1x4 Wood Purlins Detail.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL12725_R1_AE_26 Ga. Residential over 1x4 Wood Purlins Load Table.pdf FL12725_R1_AE_26 Ga. Residential Panel over 1x4 NON HVHZ Roof 2010 Format.pdf Created by Independent Third Party: Yes |
|
12725.4 |
29 Ga. Residential |
29 Ga. Residential over 15/32" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -71.75 psf @ 24” o.c. fastener spacing.-146.0 psf @ 2” o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL12725_R1_II_29 Ga. Residential over plywood detail.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL12725_R1_AE_29 Ga. Residential over plywood load table.pdf FL12725_R1_AE_29 Ga. Residential Panel over .5 Plywood NON HVHZ.pdf Created by Independent Third Party: Yes |
|
12725.5 |
29 Ga. Residential |
29 Ga. Residential over
1 x 4 Wood Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -76.75 psf @ 24” o.c. fastener spacing. -123.5 psf @ 24" o.c. fastener spacing. Install per manufacturer's details. Not for HVHZ Zones. |
Installation Instructions FL12725_R1_II_29 Ga. Residential over 1x4 Wood Purlins Detail.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL12725_R1_AE_29 Ga. Residential over 1x4 Wood Purlins Load Table.pdf FL12725_R1_AE_29 Ga. Residential Panel over 1x4 NON HVHZ.pdf Created by Independent Third Party: Yes |