2774.1 |
Guardian I or II |
Standing Seam Metal Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Minimum Roof Slope = 1/4:!2
This product is not approved for High Velocity Hurricane Zones.
Design Pressure varies depending on panel gage and span. |
Certification Agency Certificate FL2774_R5_C_CAC_CONST NO. 180B_TGKX.180B.pdf FL2774_R5_C_CAC_CONST NO. 205A_TGKX.205A.pdf FL2774_R5_C_CAC_CONST NO. 308B_TGKX.308B.pdf FL2774_R5_C_CAC_CONST NO. 534_TGKX.534.pdf FL2774_R5_C_CAC_CONST NO. 536_TGKX.536.pdf FL2774_R5_C_CAC_TJPV.R9610_CERT.pdf FL2774_R5_C_CAC_USA_UL_Insp_Dec_2011.pdf Quality Assurance Contract Expiration Date 12/31/2013 Installation Instructions FL2774_R5_II_Guardian.Installation.Manual.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
2774.2 |
Guardian-Lok |
Standing Seam Metal Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Minimum Roof Slope = 1/4:12
This product is not approved for High Velocity Hurricane Zones.
Design pressure varies depending on panel gage and span. |
Certification Agency Certificate FL2774_R5_C_CAC_CONST NO. 180C_TGKX.180C.pdf FL2774_R5_C_CAC_CONST NO. 287_TGKX.287.pdf FL2774_R5_C_CAC_CONST NO. 538_TGKX.538.pdf FL2774_R5_C_CAC_CONST NO. 539_TGKX.539.pdf FL2774_R5_C_CAC_TJPV.R9610_CERT.pdf FL2774_R5_C_CAC_USA_UL_Insp_Dec_2011.pdf Quality Assurance Contract Expiration Date 12/31/2013 Installation Instructions FL2774_R5_II_GuardianLok.Installation.Manual.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
2774.3 |
Supreme-Lok |
Standing Seam Metal Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Minimum Roof Slope = 1/4:12
This product is not approved for High Velocity Hurricane Zones.
Design Pressure varies depending on panel gage and span. |
Certification Agency Certificate FL2774_R5_C_CAC_CONST NO. 176_TGKX.176.pdf FL2774_R5_C_CAC_CONST NO. 180_TGKX.180.pdf FL2774_R5_C_CAC_CONST NO. 238B_TGKX.238B.pdf FL2774_R5_C_CAC_CONST NO. 437_TGKX.437.pdf FL2774_R5_C_CAC_TJPV.R9610_CERT.pdf FL2774_R5_C_CAC_USA_UL_Insp_Dec_2011.pdf Quality Assurance Contract Expiration Date 12/31/2013 Installation Instructions FL2774_R5_II_Supreme Lok.Installation.Manual.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
2774.4 |
Sure-Lok |
Standing Seam Metal Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Minimum Roof Slope = 1/4:12
This product is not approved for High Velocity Hurricane Zones.
Design Pressure varies depending on panel gage and span. |
Certification Agency Certificate FL2774_R5_C_CAC_CONST NO. 176_TGKX.176.pdf FL2774_R5_C_CAC_CONST NO. 180_TGKX.180.pdf FL2774_R5_C_CAC_CONST NO. 238B_TGKX.238B.pdf FL2774_R5_C_CAC_CONST NO. 437_TGKX.437.pdf FL2774_R5_C_CAC_TJPV.R9610_CERT.pdf FL2774_R5_C_CAC_USA_UL_Insp_Dec_2011.pdf Quality Assurance Contract Expiration Date 12/31/2013 Installation Instructions FL2774_R5_II_SureLok.Installation.Manual.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
2774.5 |
U.S.A.R. |
Through-fastened Metal Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Minimum Roof Slope = 1/2:12
This product is not approved for High Velocity Hurricane Zones.
Design Pressure varies depending on panel gage and span. |
Certification Agency Certificate FL2774_R5_C_CAC_CONST NO. 161_TGKX.161.pdf FL2774_R5_C_CAC_CONST NO. 167_TGKX.167.pdf FL2774_R5_C_CAC_TJPV.R9610_CERT.pdf FL2774_R5_C_CAC_USA_UL_Insp_Dec_2011.pdf Quality Assurance Contract Expiration Date 12/31/2013 Installation Instructions FL2774_R5_II_PBR_Installation_Instructions.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |