20484.1 |
5V |
Min 26 ga., 24" wide through fastened panel over 15/32" thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-169 Other: Uplift load of 71.0 psf @ fastener spacing of 24" o.c. & 169.0 psf @ fastener spacing of 6" o.c. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_1.pdf Verified By: Bala Sockalingam, P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_1.pdf Created by Independent Third Party: Yes |
|
20484.2 |
Advantage-Lok II |
Min 26 ga., 16" wide concealed fastened panel over 7/16" thick OSB & 15/32" & thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: Maximum uplift load of 116.0 psf @ seam fastener spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA rated plywood with retainer strap. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_2.pdf Verified By: Bala Sockalingam P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_2.pdf Created by Independent Third Party: Yes |
|
20484.3 |
Aluminum Advantage-Lok II |
Max 16.375" wide, nom 0.032" thick (min.) aluminum concealed fastener roof panel over min 15/32" thick plywood deck or 7/16" thick OSB. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: Uplift load of 22.5 psf at fastener spacing of 18.5" o.c. and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32" plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener spacing of 4.63" o.c. with structural sealant in 15/32" plywood. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_3.pdf Verified By: Bala Sockalingam P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_3.pdf Created by Independent Third Party: Yes |
|
20484.4 |
Aluminum SL150 |
Max 16" wide, nom 0.032" thick (min.) aluminum snap-lock standing seam metal panel over min 15/32" thick plywood deck or 7/16" thick OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and 78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16" OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with structural sealant in 15/32" plywood. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_4.pdf Verified By: Bala Sockalingam P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_4.pdf Created by Independent Third Party: Yes |
|
20484.5 |
MasterRib |
Min 29 ga., 36" wide through fastened panel over 15/32" thick plywood or 7/16" thick OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-124 Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. & 124.0 psf @ fastener spacing of 6" o.c. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_5.pdf Verified By: Bala Sockalingam, P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_5.pdf Created by Independent Third Party: Yes |
|
20484.6 |
MasterRib |
Min 29 ga., 36" wide through fastened panel over 15/32" thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-88.5 Other: Uplift load of 56 psf for Fastening System 1. Uplift load of 88.5 psf for Fastening System 2. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_6.pdf Verified By: Bala Sockalingam, P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_6.pdf Created by Independent Third Party: Yes |
|
20484.7 |
ML150 |
Max 16.5" wide, min 24 ga. steel standing seam panel over 15/32" thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-124 Other: Maximum uplift load of 124 psf @ clip spacing of 6" o.c. with 180 seam, self-adhering membrane and fixed clip. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_7.pdf Verified By: Bala Sockalingam, P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_7.pdf Created by Independent Third Party: Yes |
|
20484.8 |
PBR or R Panel |
Min 26 ga., 36" wide through fastened panel over 15/32" thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161.5 Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c. and 161.5 psf at fastener spacing of 6" o.c. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_8.pdf Verified By: Bala Sockalingam P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_8.pdf Created by Independent Third Party: Yes |
|
20484.9 |
SL175 |
Max 18" wide, min 24 ga., snap-lock standing seam metal panel over 15/32" thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and 78.6 psf @ clip spacing of 8" o.c with felt.
Uplift load of 93.5 psf @ clip spacing of 12" o.c. with self-adhering membrane. |
Installation Instructions FL20484_R1_II_EvaluationReportC2175_9.pdf Verified By: Bala Sockalingam, P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL20484_R1_AE_EvaluationReportC2175_9.pdf Created by Independent Third Party: Yes |