FL # FL20484-R1
Application Type Revision
Code Version 2017
Application Status Approved
 
Comments
Archived
 
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 813-2432
rblake@unioncorrugating.com
 
Authorized Signature Randy Blake
rblake@unioncorrugating.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL20484_R1_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
FM 44702012
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/23/2017
Date Validated 08/28/2017
Date Pending FBC Approval 09/01/2017
Date Approved 12/12/2017
Date Revised 10/10/2020
 
Summary of Products
FL # Model, Number or Name Description
20484.1 5V Min 26 ga., 24" wide through fastened panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-169
 Other: Uplift load of 71.0 psf @ fastener spacing of 24" o.c. & 169.0 psf @ fastener spacing of 6" o.c.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_1.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_1.pdf
 Created by Independent Third Party: Yes
20484.2 Advantage-Lok II Min 26 ga., 16" wide concealed fastened panel over 7/16" thick OSB & 15/32" & thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116
 Other: Maximum uplift load of 116.0 psf @ seam fastener spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA rated plywood with retainer strap.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_2.pdf
 Verified By: Bala Sockalingam P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_2.pdf
 Created by Independent Third Party: Yes
20484.3 Aluminum Advantage-Lok II Max 16.375" wide, nom 0.032" thick (min.) aluminum concealed fastener roof panel over min 15/32" thick plywood deck or 7/16" thick OSB.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: Uplift load of 22.5 psf at fastener spacing of 18.5" o.c. and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32" plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener spacing of 4.63" o.c. with structural sealant in 15/32" plywood.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_3.pdf
 Verified By: Bala Sockalingam P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_3.pdf
 Created by Independent Third Party: Yes
20484.4 Aluminum SL150 Max 16" wide, nom 0.032" thick (min.) aluminum snap-lock standing seam metal panel over min 15/32" thick plywood deck or 7/16" thick OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-86
 Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and 78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16" OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with structural sealant in 15/32" plywood.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_4.pdf
 Verified By: Bala Sockalingam P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_4.pdf
 Created by Independent Third Party: Yes
20484.5 MasterRib Min 29 ga., 36" wide through fastened panel over 15/32" thick plywood or 7/16" thick OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-124
 Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. & 124.0 psf @ fastener spacing of 6" o.c.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_5.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_5.pdf
 Created by Independent Third Party: Yes
20484.6 MasterRib Min 29 ga., 36" wide through fastened panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-88.5
 Other: Uplift load of 56 psf for Fastening System 1. Uplift load of 88.5 psf for Fastening System 2.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_6.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_6.pdf
 Created by Independent Third Party: Yes
20484.7 ML150 Max 16.5" wide, min 24 ga. steel standing seam panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-124
 Other: Maximum uplift load of 124 psf @ clip spacing of 6" o.c. with 180 seam, self-adhering membrane and fixed clip.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_7.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_7.pdf
 Created by Independent Third Party: Yes
20484.8 PBR or R Panel Min 26 ga., 36" wide through fastened panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-161.5
 Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c. and 161.5 psf at fastener spacing of 6" o.c.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_8.pdf
 Verified By: Bala Sockalingam P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_8.pdf
 Created by Independent Third Party: Yes
20484.9 SL175 Max 18" wide, min 24 ga., snap-lock standing seam metal panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and 78.6 psf @ clip spacing of 8" o.c with felt. Uplift load of 93.5 psf @ clip spacing of 12" o.c. with self-adhering membrane.
Installation Instructions
 FL20484_R1_II_EvaluationReportC2175_9.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20484_R1_AE_EvaluationReportC2175_9.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe