16648.1 |
101 All Weather Plastic Cement |
General Purpose wet / dry roof cement. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D4586 and ASTM D3409. |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.2 |
104 Asphalt concrete Primer |
General purpose asphalt primer. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D41 |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.3 |
120 Aluminum Asphalt Fibered Roof Coating |
Fibered Aluminum Roof Coating |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D2824 typeIII |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.4 |
126 Alum-Glow Non Fibered Aluminum Roof Paint |
Non Fibered Aluminum Roof Paint |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D2824 type I |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.5 |
202 Fibered Roof Coating |
Cold applied roof coating. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D4479. |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.6 |
2100 Rubberized All Weather Flashing Cement |
SBS Modified Flashing cement. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D4586 and ASTM D3409 |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.7 |
216 Modified Bitumen Adhesive |
SBS Rubberized roofing adhesive. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D3019. |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.8 |
4003 Fibered Roof Resaturant & Sealer |
Asphalt based roof resaturant. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D4479 |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.9 |
410 Quick Dry Primer |
Asphalt based quick dry roofing primer. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D41 |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.10 |
501 Premium All Weather Roofing Mastic |
Wet/Dry Roofing Mastic. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D4586 and ASTM D3409. |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.11 |
509 Modified All Weather Mastic |
Modified All Weather Roofing Mastic |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D4586 and ASTM D3409 |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.12 |
701 All Weather Flashing Cement |
Asphalt Based Flashing Cement. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D4586 and ASTM D3409 |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.13 |
711 Cold Process Lap Cement |
Cold process heavy bodied roof or interply coating |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D3019 typeIII |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.14 |
950 EternaMastic |
Acrylic Roofing Mastic. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to Dade County TAS-139 |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
16648.15 |
EternaLastic |
White Elastomeric Roof Coating |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Conforms to ASTM D6083 and TAS-143 |
Certification Agency Certificate FL16648_R0_C_CAC_TRP.DC.12050905.pdf Quality Assurance Contract Expiration Date 08/23/2016 Installation Instructions FL16648_R0_II_TRP.DC.12050905.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |